ThiSun Diurnal reproduces hourly irradiance from sunrise to sunset for 24-hour diurnal solar tests based on MIL-STD-810H Method 505.7 Procedure I.
Reproduces the hour-by-hour change in solar irradiance from dawn to midday peak to dusk, enabling 24-hour diurnal cycle tests per MIL-STD-810H Method 505.7 Procedure I.
Sunrise-to-sunset solar cycle testing to MIL-STD-810H
Why diurnal simulation matters
ThiSun Diurnal is a solar simulation system that reproduces the hourly irradiance changes from sunrise to noon to sunset required by military standards. By controlling irradiance from low levels up to the noon maximum, it repeatedly reproduces the heat accumulation and solar exposure conditions of real outdoor operation.
A diurnal solar simulation system for military standards combining Metal Halide light sources, electronic power supplies and a high-heat-resistant shutter
ThiSun Diurnal combines Metal Halide light sources, electronic power supply (EPS)-based output control and a high-heat-resistant shutter mechanism to reproduce the diurnal solar irradiation conditions of military standards.
# Metal Halide Lamp 4,000W
# Special shutter design for diurnal cycling
# Irradiance control: 55 ~ 1,120 W/m²
# One-hour / half-hour step profile operation
# Wide, symmetric beam angle for high-uniformity
LED-based solar simulation technology for next-generation military diurnal solar testing
Coming soon: an LED-based diurnal simulator for next-generation military solar testing.
# LED-based fast response and precise output control
# Continuous reproduction of low-irradiance transitions from sunrise to sunset
# Support for next-generation Military Diurnal Profiles
Operates military-standard diurnal irradiation profiles by integrating solar simulators, electronic power supplies (EPS) and shutter control systems
More than an on/off switch: the control software runs the full MIL-STD-810H diurnal profile, managing light output, shutter timing, run time, test progress, and alarms.
Profile Save & Load — Save and recall MIL profiles and customer test conditions
Shutter / EPS Control — Step control from low irradiance to peak
Real-time Monitoring — Display of irradiance, operating time, status and alarms
Group Operation — Integration with light source groups and Positioning Systems
Input Power · ThiSun 4000D: AC380V / 3PH / 4Wire / 50 ~ 60Hz
Dimming Range · ThiSun 4000D: 1% level (50% ~ 100%)
Light Source · ThiSun 4000D: Metal Halide 4,000W
Type · ThiSun 4000D: Flood Type
Spectrum Radiation · ThiSun 4000D: Full Spectrum (280 ~ 3,000nm)
Irradiance · ThiSun 4000D: 55 ~ 1,120 W/m²
Operation Temp./Humidity (EPS) · ThiSun 4000D: 0℃ ~ 35℃ / No Dew
Operation Temp./Humidity (Luminaire) · ThiSun 4000D: -10℃ ~ 50℃ / ~ 80%
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
How it differs from standard solar simulators — The key is diurnal irradiation profile control in the 55 to 1,120 W/m² range, including low-irradiance sunrise and sunset periods, rather than fixed-output or high-irradiance solar heat load tests.
Military standard-based testing — Based on the 24-hour diurnal test conditions of MIL-STD-810H Method 505.7 Procedure I, it is used to evaluate equipment temperature rise, heat load and effects on materials and electronic components.
Precise irradiance control — Combining Metal Halide light sources, electronic power supply (EPS) output control and a high-heat-resistant shutter, it precisely controls irradiance step by step from low to maximum levels.
Climate chamber integration — It can be configured as a custom solar simulation system for the customer's environment based on test object size, irradiation area, chamber conditions and applicable test standards.
ThiSun Diurnal controls irradiance from as low as 55 W/m² up to peak levels to reproduce MIL-STD-810H-based 24-hour diurnal cycle tests.
Diurnal sunlight from sunrise to sunset — Reproduces the diurnal solar cycle as it changes over time from sunrise to noon to sunset.
Diurnal Cycle
Time-varying reproduction
24-hour Profile
Precise low-irradiance control from 55 W/m² — Builds military profiles that include low-irradiance ranges difficult to achieve with general Solar Simulators.
55 W/m² low irradiance
Military Profile
Precise low-light control
High-heat-resistant shutter control — A high-heat-resistant shutter structure that withstands over 1,000℃ supports stable long-duration operation.
1,000℃+ heat resistance
High-heat-resistant shutter
Long-duration operation
Precise output control with electronic power supplies (EPS) — Combines Metal Halide Lamp output control with shutter opening and closing to support one-hour / half-hour step control.
EPS output control
Shutter integration
Step Control
Test operation based on MIL-STD-810H Procedure I — Builds a 24-hour cycle test environment suited for Cycling for Heating Effects.
MIL-STD-810H
Method 505.7
Procedure I
Custom military test system integration — System arrays and control configurations are designed for chamber size, irradiation area, test object shape and standard requirements.
Chamber Integration
Custom design
Standards compliance
MIL-STD-810H Method 505.7
Evaluating diurnal solar radiation and heat effects on US military equipment
NATO STANAG 4370 / AECTP 300 Method 305
Evaluating diurnal solar radiation and environmental resistance of NATO defense equipment
DEF-STAN 00-035 Part 3
Evaluating the durability of UK defense equipment in solar radiation and high-temperature environments
NO-06-A107
Evaluating the solar radiation durability of Polish military equipment
GJB 150.7A / 150.7B
Test standard evaluating the effects of solar radiation and environmental resistance of Chinese military equipment
Military Electronics & Sensors — Outdoor electronics, radar/sensor enclosure, display, communication equipment
Evaluating temperature rise and operational stability due to solar radiation
Checking heat load effects on electronics, sensor housings and displays
Repeatable reproduction of field deployment conditions
Ground Vehicles & Shelters — Military vehicle, shelter, containerized equipment, mobile command system
Solar loading validation of vehicle and shelter exteriors and internal electronics
Evaluating heat effects on seals, coatings, bonded joints and cable routing
Checking structural and functional changes over long repeated diurnal cycles
Outdoor Mission Equipment — Portable equipment, field power unit, defense support equipment
Sunrise–sunset thermal stress validation of outdoor equipment
Heat and weather resistance evaluation of mobile equipment, storage boxes and cases
Custom profiles reflecting user operating conditions
Aerospace & Naval Defense — Avionics, aircraft component, marine equipment, exposed outdoor systems
Solar radiation exposure evaluation of aviation and naval defense equipment
Reviewing potential degradation of paint, composites, polymers and sealants
Supporting reliability validation in combined high-temperature and solar environments
Our engineers will help you define a custom configuration and detailed specifications to match your test objectives and facility.
Purpose: Solar resistance, heat load and reliability of military equipment
MIL-STD-810H
Purpose: Marine equipment reliability under strong sun and heat
MIL-STD-810H
Purpose: Solar resistance and long-term reliability of aerospace and military parts
MIL-STD-810H
Purpose: ADAS sensor detection and malfunction under sunlight glare
A military environmental test system that reproduces the daily change of natural sunlight, the solar radiation profile from sunrise to noon to sunset, in an indoor test environment.
The ThiSun Series suits performance tests in high-irradiance environments, which covers most requirements. ThiSun Diurnal controls irradiance from as low as 55 W/m² and focuses on reproducing the diurnal cycle of MIL-STD-810H Procedure I.
The real operating environment of military equipment includes not only peak irradiance at noon but also the low irradiance of sunrise and sunset and the repeated effects of the 24-hour thermal cycle.
The main target is MIL-STD-810H Method 505.7 Solar Radiation (Sunshine), Procedure I – Cycling for Heating Effects. Depending on the project, requirements such as STANAG/AECTP, DEF-STAN and NO-06-A107 can also be reviewed.
Yes. Irradiance steps, operating time and light source groups can be configured based on standard profiles, the customer's test plan, test object shape, chamber conditions and measurement points.